Ventilation (E161065)
Katedra:ústav techniky prostředí (12116)
Zkratka:Schválen:10.06.2019
Platí do: ??Rozsah:2P+2C
Semestr:1Kredity:5
Zakončení:Z,ZKJazyk výuky:EN
Anotace
Main knowledge for design, control and evaluation of ventilation and air conditioning systems. Design according to demands for treatment of thermal and humidity state and quality of air in residential and technological rooms.
Vyučující
doc. Ing. Vladimír Zmrhal Ph.D.
Letní 2023/2024
doc. Ing. Vladimír Zmrhal Ph.D.
Letní 2022/2023
doc. Ing. Vladimír Zmrhal Ph.D.
Zimní 2021/2022
Osnova
Thermal comfort and contaminants balance in ventilated and air conditioned rooms.Air flow in rooms, supply and exhaust outlets. Air ducts, fan and piping network. Treatment of moist air in air conditioning. Heat recovery systems. Thermal load of air conditioned rooms.Dimensioning of total forced ventilation for winter and summer. Dimenzioning of all-air conditioning system.
Osnova cvičení
Practice: Thermal comfort of persons, balance of contaminants in indoor environment. Design of supply and exhaust outlets. Air network (ducts). Treatment of air in air conditioning equipments. Thermal and humidity load of rooms. Calculation of equipment for total forced ventilation. Calculation of all-air conditioning equipment.
Literatura
ASHRAE HANDBOOK. Fundamentals. Atlanta: ASHRAE, 2005. ISBN 1-931862-71-0
· ASHRAE HANDBOOK. HVAC Systems and Equipment Atlanta: ASHRAE, 2008. ISBN 978-1-933742-34-2
· Santamouris, M., Wouters, P.: Building ventilation. Earthscan. 2006. ISBN: 978-1-844-07130-2
Požadavky
Following requirements are demanded: Thermal comfort and contaminants balance in ventilated and air conditioned rooms.Air flow in rooms, supply and exhaust outlets. Air ducts, fan and piping network. Treatment of moist air in air conditioning. Heat recovery systems. Thermal load of air conditioned rooms.Dimensioning of total forced ventilation for winter and summer. Dimenzioning of all-air conditioning system.
Klíčová slova
Ventilation, air-conditioning, moist air, thermal load, air flow, system of forced total ventilation, all-air conditioning system.